Products
+
  • undefined

Gas pipeline self-closing valve

The gas pipeline self-closing valve is a new type of safety device installed at the end of indoor low-pressure gas pipelines. It connects to gas appliances via a flexible hose (or alternatively, a metal corrugated pipe) and is designed to detect gas pressure, automatically shutting off the flow while requiring manual reset. Hanyu Xing’s latest-generation smart gas pipeline self-closing valve boasts advanced technology, zero energy consumption, zero pollution, manual operation, automatic shut-off in case of gas supply interruption, automatic shut-off upon detecting excessive gas leakage or overpressure, as well as automatic indoor pressure checks—all without the need for maintenance. Currently, this product is officially promoted by China’s Ministry of Housing and Urban-Rural Development (as featured in the China Gas Equipment Design Manual) and is recommended by the China Gas Association.

Core Features

Overpressure self-closure

When the pressure regulator fails, automatically shutting off to prevent gas pressure in the pipeline from exceeding safe operating limits—thus avoiding risks such as high-pressure hose rupture or detachment, or accidental malfunctions of stoves due to excessive pressure.

Undervoltage self-shutdown

Due to malfunctions at the high-pressure station, intermittent gas supply, time-based distribution, peak-hour demands, and ice blockages—among other factors—when the gas supply pressure drops too low, the system automatically shuts off the gas source. This prevents accidents caused by flameouts or backfires resulting from abnormally low gas pressure.

Gas shut-off by self-closure

When the public gas pipeline is suddenly shut off due to emergencies, malfunctions, maintenance, or other unforeseen circumstances, this product automatically shuts down to cut off the gas supply, preventing low gas pressure that could lead to flameout or backfire—and potentially triggering accidents.

Superfluidly autistic

When the gas appliance connection hose ages, breaks, is gnawed through by rodents, or becomes loose and detached—leading to abnormal gas leakage—the product automatically shuts off and cuts off the gas supply, preventing a major leak that could cause an accident.

Indoor Leak Detection

After opening the stove valve, close the indoor main valve. If the self-closing valve shuts within 20 minutes, it indicates a gas leak in the indoor piping system—please contact your gas company’s customer service team to arrange an on-site inspection.

Technical specifications

Project

Parameters

Overpressure automatic shut-off pressure

8 kPa ± 2 kPa

Automatic shut-off pressure

0.8 kPa ± 0.2 kPa

Closing time

≤2S

Enclosure sealing performance

40 kPa test shows no leaks

Airtightness

5 kPa, Leak-Free

External dimensions

154 × 64 × 62 mm

Connection dimensions

Inlet ZG 1/2 female thread outlet
Ø9.5mm Hose Connector